cleanwear
AsepticModel CWCV001

Sterile-Ready Autoclavable Coverall Set

Coverall, booties and head cover as one sterile-ready set, designed for repeated steam autoclaving.

Cleanroom classHow clean a room is, by airborne particle count. ISO 14644-1 classes (ISO 5 to 8) or EU GMP grades (A to D).
ISO 5 to 7, Grade A to C
SterilitySupplied clean and packed so your site can sterilise it in its own validated autoclave cycle before use.
Sterile-ready, sterilise in your validated cycle
Use
Reusable
SterilisationA pressure vessel that sterilises items with saturated steam, commonly at 121 °C or 134 °C. Reusable cleanroom garments are usually autoclaved after laundering.
Steam autoclave
Colours
Blue, White, Brown
Sizes
S – 5XL
Minimum orderMinimum order quantity: the smallest order we can produce for a given item.
On request
Lead timeThe time from order confirmation (or sample approval) to dispatch.
On request
Size chartTechnical pack
  • ISO 9001 and ISO 13485 certified
  • Quote within one working day
  • Samples before bulk orders
Overview

A complete reusable gowning set for aseptic areas: coverall, knee-length booties and head cover, made from lint-free polyester with an optional antistatic carbon grid. Designed for repeated steam sterilisation and available in blue, white and brown.

This is our flagship garment for Grade AThe EU GMP zone for high risk aseptic operations such as filling and making sterile connections. Equivalent to ISO 5 for particles at rest and in operation. and B aseptic processing areas. The set is cut so the hood tucks inside the collar and the booties overlap the legs, leaving no gaps for skin or hair to shed into the room.

Each set is folded for aseptic donning and sealed in its own pouch, so operators open one pack per gowning.

Features and construction

  • Set of coverall, knee-length booties and head cover
  • Stand-up collar with snap closure and front zip with storm flap
  • Bound seams to contain fibres and particles
  • Elastic or knit cuffs and ankles, thumb loops on request
  • Snaps or loops on the legs to hold booties in place
  • Size label and batch code on every garment
  • Individually pouched, folded for aseptic donning

Where it is used

Aseptic fillingSterile APIInjectablesOphthalmicsCell and gene therapyMicrobiology labs

Standards referenced

ISO 14644-1EU GMP Annex 1
Reply within one working day.
Specifications

Sterile-Ready Autoclavable Coverall Set: specifications

Typical values. Garment life and performance depend on your laundering and sterilisation process, so validate in your own facility. Test reports are part of the technical pack.

Garment

Set contentsCoverall, knee-length booties, head coverHood and mask variants on request
ClosureFront zip with snap storm flap, stand-up collar
SeamsBound seams
Cuffs and anklesElastic or knit, thumb loops on request
Fabric optionsVBK-1120 premium, 5 mm grid or 5 mm stripe antistatic polyester
Design lifeDesigned for repeated steam autoclavingCycle life depends on your laundering and sterilisation process; confirm in your validation
SterilisationSteam autoclaveUse your validated cycle

Fabric performance (typical values)

Fabric referenceVBK-1120 antistatic twillTest report by Vestilab C.R.C. on request
Composition100% polyester filament with carbon conductive yarnTypical value, fabric mill data sheet
Weave2/1 twill, conductive yarn every 20 mmTypical value, fabric mill data sheet
Weight142 g/m²Typical value, fabric mill data sheet
Particle filtration efficiency78 at 0.3 µm, 79 at 0.5 µm %Typical value, fabric mill data sheet
Particle release4 at 0.3 µm, 2 at 0.5 µm particles per litreTypical value, fabric mill data sheet
Air permeability6.7 cc/cm²/sTypical value, fabric mill data sheet
Moisture vapour permeability7,680 g/m²/24 hTypical value, fabric mill data sheet
Surface resistivity3.5 × 10⁶ Ω/sqTypical value, fabric mill data sheet
Charge decay time0.01 s5,000 V to 10%, Typical value, fabric mill data sheet
Tear strength (warp / weft)2,550 / 2,530 gTypical value, fabric mill data sheet

Supply

ColoursBlue, white, brownOther colours on request
SizesS to 5XLSize chart in the technical pack. Custom sizes on request.
Packing1 set per sealed pouchKitting to your SOP on request
LabellingSize label and batch code on every garment
Technical pack

Everything your QA team needs to approve this product

  • Technical data sheetFabric, construction and performance dataPDF by email
  • Size chartBody measurements for every sizePDF by email
  • Care and autoclave guideLaundering, sterilisation and cycle trackingPDF by email
  • CertificatesISO 9001, ISO 13485 and fabric test reportPDF by email

Email me the technical pack

Sent to your inbox within one working day. Only the documents you asked for.

Sterile-Ready Autoclavable Coverall Set: questions buyers ask

How many times can the coverall set be autoclaved?

The set is designed for repeated steam autoclaving. The exact number depends on the fabric grade and on your laundering and sterilisation parameters, so we recommend tracking cycles per garment and inspecting before each use.

Does the set come sterile?

Sets can be supplied ready for your own sterilisation, which is how most plants run them, or discuss pre-sterilised supply with our team.

Which colour should I choose?

Many plants use colour to separate zones, for example white for Grade A/B, blue for Grade C and brown for support areas. We can match your existing colour code.

Can I get a sample?

Yes. Request a sample with your size and ISO class and we will confirm within one working day.

Complete the set

Often ordered together

Pullover Cleanroom Hood, product photo on white
Aseptic
CWHD001

Pullover Cleanroom Hood

Eyes-only hood that tucks into the coverall collar.

ISO 5 to 7For sterile or non-sterile areas
View specifications
Two-Piece Cleanroom Undergarment, product photo on white
Controlled
CWUG001

Two-Piece Cleanroom Undergarment

Lint-free shirt and trouser worn under the coverall instead of street clothes.

ISO 5 to 8
View specifications
Switching supplier?

Send us the garment you use today

Share the competitor part number, a photo or a sample piece. We match the specification or suggest an equivalent, with a sample for your trial.

Reply within one working day.

Tell us what your cleanroom needs

Share your ISO class, quantities and timelines. We reply with options, a quote and sample availability within one working day.